What happened?
A vessel suffered flooding and loss of integrity, caused by sea water ingress into the engine room, due to a hole developing in the box cooler bulkhead.
A high level bilge alarm occurred at night. It was found that there was significant water ingress in the engine room. The Master raised the alarm and the crew were mustered. A little over an hour later a hole with diameter 1cm was found on a box cooler bulkhead. The flooding was brought under control using hand pumps. The Master and Chief Engineer assessed the situation as an emergency and decided to return the vessel to port immediately. Continuous monitoring and double watch was maintained in the engine room.
The vessel had to be dry-docked for repairs which were estimated would take two days.
What went wrong? What were the causes?
Subsequent inspection in dry dock revealed that the aft bulkhead and inboard longitudinal bulkhead for the aft of the two forward box coolers had more corrosion problems than the one hole in the aft bulkhead. The inboard longitudinal bulkhead was severely pitted over (approximately) its upper half. The aft bulkhead had isolated areas of deep corrosion, also predominantly at its upper half. All other sea chests were internally examined, and no substantial corrosion found.
There was no indication at survey that the insulators of the copper anodes of the marine growth prevention system (ICAF) had failed or that the power supply wires had failed leading to the possibility of stray currents from the system. It was not possible to verify the correlation between the reported malfunction of the ICAF system (marine growth protection) and the observed substantial corrosion.
What actions were taken?
- Following repairs, additional sacrificial anodes were installed;
- Possible installation of an impressed current cathodic protection (ICCP) system, which further improves corrosion protection.
Our member notes that box coolers are sometimes assumed to be maintenance free. However, the incident has shown that a particular attention should be exercised to the area in connection with dry-docking and the system condition and performance should be regularly verified.
Sheron Dienhart says
Honestly i’am not good at reading but your blog is really easy to understand, thanks for sharing…
weight loss says
this is a unique insight you have!
Magazines for Sale online says
545616 219575Oh my goodness! a amazing write-up dude. Thanks a good deal Nonetheless We are experiencing trouble with ur rss . Do not know why Not able to sign up to it. Maybe there is anybody finding identical rss difficulty? Anyone who knows kindly respond. Thnkx 832303
mơ thấy người cha đã mất says
599580 741981I like this post, enjoyed this 1 regards for posting . 667858